Obstructive Sleep Apnea Diagnosis and Treatment - part 2

Giám sát kỹ thuật số của hơi thở bị rối loạn giấc ngủ bằng cách sử dụng âm thanh ngáy ngủ và độ bão hòa oxy động mạch. Am Rev Respir Dis năm 1993; 148:1023-1029. 54. J Vazquez, Tsai W, Flemons W, et al. Tự động phân tích oxy kỹ thuật số trong chẩn đoán ngưng thở khi ngủ do tắc nghẽn. | Screening and Case Finding 33 53. Issa FG Morrison D Hadjuk E et al. Digital monitoring of sleep disordered breathing using snoring sound and arterial oxygen saturation. Am Rev Respir Dis 1993 148 1023-1029. 54. Vazquez J Tsai W Flemons W et al. Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea. Thorax 2000 55 302-307. 55. West P George CFP Kryger MH. Dynamic in vivo response characteristics of three oximeters Hewlettpackard 47201A Biox III and Nellcor N-100. Sleep 1987 10 263-271. 56. Severinghaus JW Naifeh KH Koh SO. Errors in 14 pulse oximeters during profound hypoxia. J Clin Monit 1989 5 72-81. 57. Vegfors M Lindberg Lennmarken C. The influence of changes in blood flow on the accuracy of pulse oximetry in humans. Acta Anaesthesiol Scand 1992 36 346-349. 58. Kirk VG Bohn SG Flemons WW et al. Comparison of home oximetry monitoring with laboratory polysomnography. Chest 2003 124 1702-1708. 59. Stoohs R Guilleminault C. MESAM 4 an ambulatory device for the detection of patients at risk for obstructive sleep apnea syndrome OSAS . Chest 1992 101 1221-1227. 60. Koziej M Cieslicki J Gorzelak K et al. Hand-scoring of MESAM 4 recordings is more accurate than automatic analysis in screening for obstructive sleep apnoea. Eur Respir J 1994 7 1771-1775. 61. Esnaola S Duran J Infante-Rivard C et al. Diagnostic accuracy of a portable recording device MESAM IV in suspected obstructive sleep apnea. Eur Respir J 1996 9 2597-2605. 62. Cirignotta F Mondini S Gerardi R et al. Unreliability of automatic scoring of MESAM 4 in assessing patients with complicated obstructive sleep apnea syndrome. Chest 2001 119 1387-1392. 63. Fietze I Dingli K Diefenbach K et al. Night-to-night variation of the oxygen desaturation index in sleep apnoea syndrome. Eur Respir J 2004 24 987-993. 64. Westbrook PR Levendowski DJ Cvetinovic M et al. Description and validation of the apnea risk evaluation system a novel method to diagnose sleep apnea-hypopnea in the home.

Không thể tạo bản xem trước, hãy bấm tải xuống
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.