Báo cáo y học: "Reliability of the TekScan MatScan® system for the measurement of plantar forces and pressures during barefoot level walking in healthy adults"

Tuyển tập báo cáo các nghiên cứu khoa học quốc tế ngành y học dành cho các bạn tham khảo đề tài: Reliability of the TekScan MatScan® system for the measurement of plantar forces and pressures during barefoot level walking in healthy adults. | Zammit et al. Journal of Foot and Ankle Research 2010 3 11 http content 3 1 11 JOURNAL OF FOOT AND ANKLE RESEARCH RESEARCH Open Access Reliability of the TekScan MatScan system for the measurement of plantar forces and pressures during barefoot level walking in healthy adults Gerard VZammit 1 Hylton B Menz1 and Shannon E Munteanu1 2 Abstract Background Plantar pressure systems are increasingly being used to evaluate foot function in both research settings and in clinical practice. The purpose of this study was to investigate the reliability of the TekScan MatScan system in assessing plantar forces and pressures during barefoot level walking. Methods Thirty participants were assessed for the reliability of measurements taken one week apart for the variables maximum force peak pressure and average pressure. The following seven regions of the foot were investigated heel midfoot 3rd-5th metatarsophalangeal joint 2nd metatarsophalangeal joint 1st metatarsophalangeal joint hallux and the lesser toes. Results Reliability was assessed using both the mean and the median values of three repeated trials. The system displayed moderate to good reliability of mean and median calculations for the three analysed variables across all seven regions as indicated by intra-class correlation coefficients ranging from to for the mean and to for the median and coefficients of variation ranging from 5 to 20 for the mean and 3 to 23 for the median. Selecting the median value of three repeated trials yielded slightly more reliable results than the mean. Conclusions These findings indicate that the TekScan MatScan system demonstrates generally moderate to good reliability. Background During functional activities such as walking the human foot exerts a force upon the underlying surface and in turn a force of equal magnitude and opposite direction is exerted upon the foot. This force is commonly termed the ground reaction force 1 2 . Technological .

Không thể tạo bản xem trước, hãy bấm tải xuống
TÀI LIỆU LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.