Nondestructive Evaluation and Quality Control (1998) Part 9

Tham khảo tài liệu 'nondestructive evaluation and quality control (1998) part 9', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 39. . Joseph Artifacts in Computed Tomography Phys. Med. Biol. Vol 23 1978 p 1176-1182 40. . Brooks et al. Aliasing A Source of Streaks in Computed Tomograms J. Comput. Asst. Tomgr. Vol 3 No. 4 1979 p 511-518 41. . Chesler et al. Noise Due to Photon Counting Statistics in Computed X-Ray Tomography J. Comput. Asst. Tomgr Vol 1 No. 1 1977 p 64-74 42. . Hanson Detectability in Computed Tomographic Images Med. Phys. Vol 6 No. 5 1979 43. . McDavid . Waggener . Payne and . Dennis Spectral Effects on Three-Dimensional Reconstruction From X-Rays Med. Phys. Vol 2 No. 6 1975 p 321-324 44. . Joseph and . Spital A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners J. Comput. Asst. Tomogr. Vol 2 No. 3 1978 p 100-108 Industrial Computed Tomography Michael J. Dennis General Electric Company NDE Systems and Services Special Features The components that constitute a CT system often allow for additional flexibility and capabilities beyond providing the cross-sectional CT images. The x-ray source detector and manipulation system provide the ability to acquire conventional radiographic images. The acquisition of digital images along with the computer system facilitates the use of image processing and automated analysis. In addition the availability of the cross-sectional data permits threedimensional data processing image generation and analysis. Digital Radiography. One of the limitations of CT inspection is that the CT image provides detailed information only over the limited volume of the cross-sectional slice. Full inspection of the entire volume of a component with computed tomography requires many slices limiting the inspection throughput of the system. Therefore CT equipment is often used in a DR mode during production operations with the CT imaging mode used for specific critical areas or to obtain more detailed information on indications found in the DR image. Digital radiography capabilities and throughput can be .

Không thể tạo bản xem trước, hãy bấm tải xuống
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
24    19    1    27-11-2024
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.