Nuclear Power Operation Safety and Environment Part 8

Tham khảo tài liệu 'nuclear power operation safety and environment part 8', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Imaging of Radiation Accidentsand Radioactive Contamination Using Scintillators 199 Fig. 15. Streak camera image of the fluorescence from ZnO. This is a 50000-shot integrated signal excited by 56 nm. The vertical axis is wavelength nanometer and the horizontal axis is time nanosecond . The dominant fluorescence peak was centered at around 380 nm. Fig. 16. Temporal profiles of the ZnO fluorescence excited by a 51nm b 56nm and c 61 nm. The observed profiles can be fitted by double exponential decays described as I A1 exp -t t1 A2 exp -t T2 dotted line . The fitting parameters are A1 A2 T1 70ps and T2 estimated instrumental function was plotted with a dot line in each graph. d Slit image dotted line and a calculated curve of a convolution of the slit image and a normal distribution function solid line . 200 Nuclear Power - Operation Safety and Environment Initially the response time of Fe-ion doped ZnO scintillator was evaluated using the third harmonics of a mode-locked Ti sapphire femtosecond laser at 290nm. The typical band-to-band ultraviolet fluorescence at 380nm was successfully observed with a decay time of 80ps. This is significantly faster compared with the previously reported 1-ns decay time for the 380-nm fluorescence of undoped ZnO. The 1x1cm2 thick double-side polished ZnO crystal was mounted in a vacuum chamber and the third harmonics of a neodymium-doped YAG Nd YAG laser was initially used as excitation for alignment purposes. The sample was illuminated from the backside in a counter propagation configuration with the beam path of the SCSS test accelerator as shown in Fig. 14. The SCSS test accelerator having 200-fs pulse duration 10-uJpulse energy and 20-Hz repetition rate was focused by an oblique mirror Mimura et al. 2008 . With a mirror focal length of 1m the spot size at the focus was about 20 pm. To minimize the risk of damage however the sample was placed 5 cm away from focus and the radius of the beam at this location

Không thể tạo bản xem trước, hãy bấm tải xuống
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.