Wind Farm Impact in Power System and Alternatives to Improve the Integration P13

Công nghệ cơ khí thường tạo ra các giả lập mô phỏng hoạt động của các đối tượng, như quy trình chế tạo thực tế theo trình tự tối ưu hóa sự thực hiện, hiệu quả kinh tế và chi phí năng lượng trước khi quyết định lựa chọn một thiết kế cụ thể. | Modelling and Simulation of a 12 MW Active-Stall Constant-Speed Wind Farm 289 Transmission model simulation during start-up The aerodynamic torque torque_rot-Trot accelerates the wind turbine rotor with the generator disconnected from the grid until the rotor speed omega_rot-fflrot is close to its nominal value. Then the generator is connected to the grid as seen in Fig. 16. The basic idea is to control the rotational speed using only measurement of the power or torque as it is depicted in Fig. 1 and by equations 1 and 2 as well. Fig. 16. Transmission model during start-up. Aerodynamic torque torque_rot mechanical torque torque_mec generator speed omega_gen and rotor speed omega_rot of wind turbine system. Simulation results during start-up normal operation and heavy transients The control strategy of active stall constant speed wind turbine contains three modes of operation acceleration control speed control power control power limiting region and direct pitch control blade angle control . The acceleration and pitch control modes are used during start-up shut down and emergency conditions while the power control mode is only used during normal operations. Figure 17 shows how a 2 MW wind turbine with constant speed works during different operation conditions such as sudden changes in wind speed wind gusts with a turbulence intensity of 12 at high wind speed. 290 Wind Farm - Impact in Power System and Alternatives to Improve the Integration Fig. 17. Simulation results during sudden changes in wind speed for a 2MW active stall constant-speed wind turbine using CRIG. In Fig. 18 the 2 MW induction generator was connected to the grid through a soft-starter in order to reduce the transient current at t 73 seconds and then the soft-starter was bypassed at t 77 seconds. In the same time the power factor compensation unit started to work using capacitor switching as a function of average value of measured reactive power. The mean wind speed was 12 m s. At t 100 .

Không thể tạo bản xem trước, hãy bấm tải xuống
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
24    69    2    12-05-2024
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.