báo cáo hóa học:" The suitability of an uncemented hydroxyapatite coated (HAC) hip hemiarthroplasty stem for intracapsular femoral neck fractures in osteoporotic elderly patients: the Metaphyseal-Diaphyseal index, a solution to preventing intra-operative periprosthetic fracture"

Tuyển tập các báo cáo nghiên cứu về hóa học được đăng trên tạp chí sinh học quốc tế đề tài : The suitability of an uncemented hydroxyapatite coated (HAC) hip hemiarthroplasty stem for intracapsular femoral neck fractures in osteoporotic elderly patients: the Metaphyseal-Diaphyseal index, a solution to preventing intra-operative periprosthetic fracture | Chana et al. Journal of Orthopaedic Surgery and Research 2011 6 59 http content 6 1 59 JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH RESEARCH ARTICLE Open Access The suitability of an uncemented hydroxyapatite coated HAC hip hemiarthroplasty stem for intra-capsular femoral neck fractures in osteoporotic elderly patients the Metaphyseal-Diaphyseal index a solution to preventing intra-operative periprosthetic fracture Rishi Chana1 Reza Mansouri1 Chris Jack1 Max R Edwards2 Ravi Singh3 Carmel Keller4 and Farid Khan1 Abstract This study will seek to identify a measurable radiographic index the Metaphyseal-Diaphyseal Index MDI score to determine whether intra-operative fracture in osteoporotic bone can be predicted. A 5 year prospective cohort of 560 consecutive patients undergoing hemiarthroplasty cemented or uncemented was evaluated. A nested case-control study to determine risk factors affecting intra-operative fracture was carried out. The Vancouver Classification was used to classify periprosthetic fracture. The MDI score was calculated using radiographs from the uncemented group. As a control gold standard Yeung et al s Canal Bone Ratio CBR score was also calculated. From this a receiver operating characteristic ROC curve was formulated for both scores and area under the curve AUC compared. Intra and inter-observer correlations were determined. Cost analysis was also worked out for adverse outcomes. Four hundred and seven uncemented and one hundred and fifty-three cemented stems were implanted. The use of uncemented implants was the main risk factor for intra-operative periprosthetic fracture. Sixty-two periprosthetic fractures occurred in the uncemented group nine occurred in the cemented group P . The revision rate for sustaining a periprosthetic fracture uncemented group was P and 90 day mortality P . MDI s AUC was compared to CBR s P . The MDI score cut-off to predict fracture was 21 .

Không thể tạo bản xem trước, hãy bấm tải xuống
TÀI LIỆU LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.