KRONE - Guide Book - Patch by Exception - How it works

Patch by Exception is a jumpered Block cabling solution with the flexibility of overriding jumpers with the simple use of a Patch Cord. This effectively provides the simplicity of an RJ solution without the need for patch management, eliminating messy wiring. Clipsal 3104 Series Patch by Exception modules guarantee excellent high output transmission performance. | Patch by Exception - How does it work Patch-By-Exception is a solution whereby you hard wire your network and make subsequent changes utilising patch cords. The diagram shows a patch cord changing the input from workstation one to workstation two. The cord disconnects the jumpers leading to workstation one and re-directs the signal through the patch cord to workstation two. To go back to the original configuration simply remove the patch cord. If the change is to be made permanent a cabling specialist can be called in to hard wire the configuration and the removed patch cord can be reused for other temporary changes. Features and Benefits Permanent services are hardwired rather than patched This provides a neat and tidy cable management solution and allows for greater flexibility of wiring arrangements and superior reliability. Data side frame does not need to be co-located with active equipment Reduces cabinet and floor space requirements and costs. Is particularly effective with high density Telco connectorised hubs which allows further cabinet space reductions. Category 5 or 6 cable is used instead of This method is more cost effective as jumper cable is cheaper patch cords. than the equivalent length of patch cord. Performance is enhanced due to the lower attenuation of jumper cable and the elimination of one plug and socket in the channel. Extensive labelling options More information can be displayed on the modules reducing the need to refer to other documentation. 19 inch racks are not required. Makes this solution cost effective as 19 inch racks are more expensive. Fits in shallow wall recesses or closets. Capacity for mounting with existing LSA modules Cost Reduction. Testing convenience Suspected faulty hub or PABX ports can be tested or rerouted to locate problems without losing the underlying .

Bấm vào đây để xem trước nội dung
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.