Amperometric biosensor for detection of triglyceride tributyrin based on zero point charge of activated carbon

A simple and robust single enzyme biosensor was fabricated for triglyceride (TG) detection. Graphite rods were modified with activated carbon (AC) and used as support for lipase immobilization. Chitosan (CHIT) was eventually used to create film on the bioelectrode and retain the immobilized enzyme. | Turkish Journal of Biology Turk J Biol (2017) 41: 268-277 © TÜBİTAK doi: Research Article Amperometric biosensor for detection of triglyceride tributyrin based on zero point charge of activated carbon 1 1, 1 2 Mohsen REZVANI , Ghasem D. NAJAFPOUR *, Maedeh MOHAMMADI , Hossein ZARE Biotechnology Research Laboratory, Faculty of Chemical Engineering, Babol Noushirvani University of Technology, Babol, Iran 2 Buein Zahra Technical University, Buein Zahra, Qazvin, Iran 1 Received: Accepted/Published Online: Final Version: Abstract: A simple and robust single enzyme biosensor was fabricated for triglyceride (TG) detection. Graphite rods were modified with activated carbon (AC) and used as support for lipase immobilization. Chitosan (CHIT) was eventually used to create film on the bioelectrode and retain the immobilized enzyme. To extend the linear range of TG detection, AC was functionalized with carboxyl and then amine groups (AAC) to enhance the isoelectric point of AC. The constructed graphite/AAC/lipase /CHIT bioelectrode was characterized using cyclic voltammetry and field emission scanning electron microscopy (FE-SEM). The accuracy of the developed biosensor was assessed through determination of different concentrations of tributyrin (TB) in buffer solution. Linear responses were found for TB concentration in the range of 50 to 350 mg dL–1 with a detection limit of mg dL–1. The biosensor showed good sensitivity of µA mg–1 dL. The detected level of TG in several human serum specimens using the constructed biosensor was in good agreement with the results of an automatic biochemical analyzer. The fabricated biosensor was not affected by a number of human serum materials and showed a strong anti-interference ability. The relative standard deviation in reproducibility and repeatability tests was and , respectively. Key words: Activated carbon, .

Không thể tạo bản xem trước, hãy bấm tải xuống
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
463    20    1    28-11-2024
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.