Concentration of sodium dodecyl sulfate used in occlusion body extraction affects Spodoptera littoralis nucleopolyhedrovirus biological activity

Efficacy of a baculovirus as a biological control agent is evaluated according to biological parameters, median lethal dose (LD50) of the virus, and median lethal time (LT50) of infected larvae. | Turkish Journal of Biology Research Article Turk J Biol (2013) 37: 171-175 © TÜBİTAK doi: Concentration of sodium dodecyl sulfate used in occlusion body extraction affects Spodoptera littoralis nucleopolyhedrovirus biological activity* 1 2, 2 Hilal SUSURLUK , Umut TOPRAK **, Mehmet Oktay GÜRKAN Bursa Province Directorate of Ministry of Food, Agriculture, and Livestock, Hürriyet, Bursa, Turkey 2 Department of Plant Protection, Faculty of Agriculture, Ankara University, Dışkapı, Ankara, Turkey 1 Received: Accepted: Published Online: Printed: Abstract: Efficacy of a baculovirus as a biological control agent is evaluated according to biological parameters, median lethal dose (LD50) of the virus, and median lethal time (LT50) of infected larvae. Sodium dodecyl sulfate (SDS) is commonly used in concentrations of –1% to extract infective units of the baculoviruses, occlusion bodies (OBs), from infected cadavers. Although several studies have shown disruption of OB structure by SDS, the effects of SDS concentrations on baculovirus biological parameters are not well known. Indeed, it is essential to detect the optimum SDS concentration for OB extraction to compare the activity of baculoviruses accurately. In our study, the effects of SDS (–2%) on baculoviral biological activity were examined using Spodoptera littoralis nucleopolyhedrovirus in third instar Spodoptera littoralis (Lepidoptera: Noctuidae) larvae. Use of 1% SDS in OB extraction caused the lowest LD50, while higher concentrations than 1% significantly increased the LD50. The differences between LT50 values at –1% SDS were found to be insignificant; however, higher concentrations (>) caused significant loss of biological activity. Therefore, – SDS could be used for OB extraction; however, evaluation of LD50 and LT50 values together suggests that 1% SDS provides the best .

Không thể tạo bản xem trước, hãy bấm tải xuống
TÀI LIỆU LIÊN QUAN
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
2    107    2    28-04-2024
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.