Optimizing dimension of heat sink’s plate fin with the effect of wind velocity in site router tecommunication system

In this paper, the author presents the optimal calculation and control process of the size of the heat sink and the contact plate under the influence of actual operation conditions at the specified velocity of the air flow from which the model is built directly to determine the number and the size of the heat sink’s plate fins. | ISSN 1859-1531 - THE UNIVERSITY OF DANANG, JOURNAL OF SCIENCE AND TECHNOLOGY, NO. 12(133).2018 19 OPTIMIZING DIMENSION OF HEAT SINK’S PLATE FIN WITH THE EFFECT OF WIND VELOCITY IN SITE ROUTER TECOMMUNICATION SYSTEM Viet Dang-Thai, Thong Dinh-Sy Hanoi University of Science and Technology; , dinhsythong@ Abstract - Nowadays, heat dissipation for electronic chips, microprocessors in electrical and electronic equipment, especially in Site Router telecommunication equipment when operating at high intensity is an urgent process to increase life expectancy, productivity and performance. Many telecom providers such as Huawei, Ericsson, Cisco etc have offered solutions for liquid cooling, cold air, heat pipes. However, the complexity, the cost and the effect are not high. Furthermore, there is shortage in optimal parameters of design and operation [1-5]. Derived from the above fact, the author has calculated and modeled a Site Router equipment using extruded blast heat exchanger with a large heat exchanger structure which withstands pressure when falling, combining airflow from fans to speed up the dissipation of heat. In this paper, the author presents the optimal calculation and control process of the size of the heat sink and the contact plate under the influence of actual operation conditions at the specified velocity of the air flow from which the model is built directly to determine the number and the size of the heat sink’s plate fins. Key words - Airflow; cooling process; heat dissipation; optimal control; SiteRouter equipment. 1. Nomanclature A: Surface area in m2. Ac: Cross-sectional area in m2. Af = : Total frontal area of heatsink. Ap: Fin profile area. α: The convective heat transfer coefficient depends on a number of parameters determined by experiment (W/). b: Fin spacing in m. C=120: Sutherland's constant for air. F: surface area of heat exchanger (m2). H: Fin height in m. k= 209: Thermal conductivity of Al6063-T5

Không thể tạo bản xem trước, hãy bấm tải xuống
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.