Simulation and design of individual neutron dosimeter and optimization of energy response using an array of semiconductor sensors

The performance of the simulation scheme has been compared with the commercial and laboratory samples in the world. Due to the deviation of all dosimeters with a flat energy response, in this paper, has been used an idea of one semi-conductor sensor to have the flat energy-response in the entire neutron energy range. Finally, by analyzing of the sensors data as arrays for the first time, we have reached a nearly flat and acceptable energy-response. | Simulation and design of individual neutron dosimeter and optimization of energy response using an array of semiconductor sensors Nuclear Engineering and Technology 51 (2019) 293e302 Contents lists available at ScienceDirect Nuclear Engineering and Technology journal homepage: Original Article Simulation and design of individual neutron dosimeter and optimization of energy response using an array of semiconductor sensors R. Noushinmehr a, A. Moussavi zarandi a, *, M. Hassanzadeh b, F. Payervand c a Nuclear Engineering and Physics Faculty, Amirkabir University of Technology, Tehran, Iran b Nuclear Science and Technology Research Institute (NSTRI), Reactor and Nuclear Safety School, Tehran, Iran c Nuclear Science and Technology Research Institute (NSTRI), Radiation Application Research School, Tehran, Iran a r t i c l e i n f o a b s t r a c t Article history: Many researches have been done to develop and improve the performance of personal (individual) Received 17 February 2018 dosimeter response to cover a wide of neutron energy range (from thermal to fast). Depending on the Received in revised form individual category of the dosimeter, the semiconductor sensor has been used to simplify and light- 21 April 2018 weight. In this plan, it’s very important to have a fairly accurate counting of doses rate in different en- Accepted 14 September 2018 Available online 15 September 2018 ergies. With a general design and single-sensor simulations, all optimal thicknesses have been extracted. The performance of the simulation scheme has been compared with the commercial and laboratory samples in the world. Due to the deviation of all dosimeters with a flat energy response, in this paper, has Keywords: Neutron dosimeter been used an idea of one semi-conductor sensor to have the flat energy-response in the entire neutron Semiconductor energy range. Finally, by analyzing of the sensors data

Không thể tạo bản xem trước, hãy bấm tải xuống
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.