Evaluation of hydraulic energy nozzle suitable for low velocity air-assisted sprayer

Performance evaluation of commercially available hydraulic energy nozzles (HCN/PB, HCN/PC, HCN/PD and HCN/PE) used in manually operated sprayer was conducted to identify the suitable nozzle for low velocity air-assisted sprayer. The discharge rate, droplet size, droplet size distribution pattern and spray distribution pattern of all the types of nozzles were measured with a pressure range of to MPa at an interval of MPa. It was found that with the increase in pressure from to MPa, the discharge rate, swath width and spray angle increased for all the four types of nozzles. At all working pressures, the discharge rate and spray width is higher for HCN/PE nozzle followed by HCN/PD, HCN/PC and HCN/PB. The discharge rate of HCN/PB nozzle (363 to 533 ml/min) was found suitable for cotton crop. | Evaluation of hydraulic energy nozzle suitable for low velocity air-assisted sprayer