Cathodic polarization is investigated as a technique for CRUD build-up mitigation in simulated primary pressurized water reactor conditions and accelerated flow. This investigation showed that the application of 3 V could induce a 67% reduction in surface deposition whilst 30 V cell voltage completely prevented the formation of surface deposits. |