Lab 5.1.4 RJ-45 Jack Punch Down

In this lab, the student will learn to wire an RJ-45 data jack for installation in a wall plate using a punch-down tool. These skills are useful when it is necessary to install a small amount of cabling in an office or residence. A punch tool is a device that uses spring-loaded action to push wires between metal pins, while at the same time skinning the sheath away from the wire. This ensures that the wire makes a good electrical connection with the pins inside the jack. The punch tool also cuts off any extra wire | Cisco SrsTEMS Lab RJ-45 Jack Punch Down Objective Learn the correct process for terminating or punching down an RJ-45 jack Learn the correct procedure for installing the jack in a wall plate Background Preparation In this lab the student will learn to wire an RJ-45 data jack for installation in a wall plate using a punch-down tool. These skills are useful when it is necessary to install a small amount of cabling in an office or residence. A punch tool is a device that uses spring-loaded action to push wires between metal pins while at the same time skinning the sheath away from the wire. This ensures that the wire makes a good electrical connection with the pins inside the jack. The punch tool also cuts off any extra wire. CAT 5 or CAT 5e cabling and CAT 5 or 5e rated T568-B jacks will be used. A CAT 5 5e straight-wired patch cable with an RJ-45 connector will normally plug into this data jack or outlet to connect a PC in a work area to the network. It is important to use CAT 5 or 5e rated jacks and patch panels with CAT 5 or 5e cabling in order to support Fast Ethernet 100 Mbps and Gigabit Ethernet 1000 Mbps . The process of punching down wires into a data jack in an office area is the same as punching them down in a patch panel in a wiring closet. The following resources are required 60 - 90 cm 2 - 3 feet length of CAT 5 5e cabling which can be one per person or one per team Two CAT 5 5e RJ-45 data jacks one extra for spare - If RJ-45 data jacks are installed on both ends of the cable the installation can be tested by inserting cable with RJ-45 connectors and a simple cable continuity tester. CAT 5 5e wall plate 110 type punch-down tool Wire cutters Use the following procedure and diagram to punch down the wires into the RJ-45 jack and install the jack into the wall plate Step 1 Remove the jacket cm 1 inch from the end of the cable. Step 2 Position wires in the proper channels on the jack maintaining the twists as closely as possible. The diagram below

Bấm vào đây để xem trước nội dung
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.