Báo cáo nghiên cứu khoa học: " FAST CALCULATING FORMULAS OF CURRENT PASSING THROUGH GROUNDING SYSTEM OF HIGH VOLTAGE SUBSTATION WHEN LIGHTNING STRIKES AT THE GROUNDING WIRE OF TRANSMISSION LINE"

Hiện tại tiêm một hệ thống nối đất trạm biến áp điện áp cao quyết định biên độ và phân phối điện áp dọc theo mạng lưới nền tảng [1] - [2]. Do đó, việc xác định dòng ngắn mạch tại trạm biến áp là luôn luôn được chăm sóc bởi các nhà thiết kế. | Science Technology Development Vol 11 - 2008 FAST CALCULATING FORMULAS OF CURRENT PASSING THROUGH GROUNDING SYSTEM OF HIGH VOLTAGE SUBSTATION WHEN LIGHTNING STRIKES AT THE GROUNDING WIRE OF TRANSMISSION LINE Ho Van Nhat Chuong University of Technology VNU-HCM Manuscript Received on September 21st 2007 Manuscript Revised May 27th 2008 ABSTRACT Current injecting a grounding system of high voltage substation decides the amplitude and the voltage distribution along the grounding grid 1 - 2 . Therefore the determination of short circuit current at substation is always cared by the designers. This paper presents a method to fast calculate the current passing through grounding system of high voltage substation when lightning strikes at the grounding wire of transmission line. 1. INTRODUCTION To calculate the current of lightning exactly we must not only apply numerical analysis but also use computer. This problem requires that users need to have professional knowledge and the ability of programming or using specialized software that are very expensive. Thus this paper presents some new formulas to calculate the current passing through grounding system of high voltage substation when lightning strikes at the grounding wire of transmission line. Fig 1. Equivalent circuit of grounding wire line Based on transmission line models 3 - 5 the grounding wire system can be modeled as equivalent circuit . Where n is the number of span each span is represented by a pi-circuit. The shunt impedance Zp is the grounding impedance of pole and the series impedance Zs is the impedance of grounding wire if the transmission line has two grounding wires then this series impedance will be Zs 2 . Z1 is the impedance of grounding system of the first substation and Z2 is the impedance of grounding system of the second substation. In case of open-ended grounding wire line Z2 . The system of grounding wire and impedance of pole can be modeled as a series of connected n pi-elements .

Không thể tạo bản xem trước, hãy bấm tải xuống
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
150    68    2    29-04-2024
196    59    1    29-04-2024
34    401    5    29-04-2024
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.