equipment test

Aluminum oxide dosage: Is under the point if " aluminum oxide in-proportion -YES - NO " with a cross, means this, the aluminum dosage before the mill must be switched on. This does not apply however to the system attempt, aluminum dosage both for production is only connected. The following is to be considered: | PB-Nr Machine test 1 Process description Aluminum oxide dosage Is under the point if aluminum oxide in-proportion -YES - NO with a cross means this the aluminum dosage before the mill must be switched on. This does not apply however to the system attempt aluminum dosage both for production is only connected. The following is to be considered The Funnel must be filled with aluminum oxide 010565 . The dosage is to be stopped over potentiometer. The performance of the system is to be determined with the attempt over the system. Usually aluminum oxide is metered . 0 2 Dosage Output kg h dosing adjustment 87 10 110 20 133 30 166 40 200 50 245 60 291 70 344 80 397 90 467 100 0 3 Dosage Output kg h Dosing adjustment 58 10 73 20 89 30 111 40 133 50 163 60 194 70 229 80 265 90 311 100 should result 58 10 73 20 89 30 111 40 133 50 163 60 194 70 229 80 265 90 311 100 in the course of production then the dosing adjustment is to be modified accordingly. Issued by Date of release Version Page Hr. Demmelmayer 0 1 4 PB-Nr Machine test 2 Line-up of extrusion Acceptance - deadlock of the complete system heating switched off. System diseased and removed. The heaters water - or oil pre-heaters are switched on and adjusted to 110 C. With water devices the water dosage is closed in order to enable a faster heating. The nozzle heating is stopped to 120 C. If the adjusted values are achieved -10 C extrusion is switched on whereby it is to be made sure that the potentiometers is adjusted to the fact to lowest number of revolutions danger of a planet break The smallest adjustment detects one that the potentiometers no more cannot be adjusted against the clockwise direction. Extrusion is adjusted to be switched on the values given on the product route card. The water dosage of the heaters is again opened. 3 Line-up of the mill 3-1 Manual Separator adjustment according to product route card. Fan rotor timer product discharge cyclone product supply mill max. speed .

Bấm vào đây để xem trước nội dung
TÀI LIỆU MỚI ĐĂNG
187    27    1    01-12-2024
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.