Guide for Sound Insulation in Wood Frame Construction Part 9

Các tấm mở rộng thông qua các sàn khoang dưới của subfloor. Các lớp cơ sở gắn theo chiều dọc bằng cách sử dụng 1-5/8 "(42 mm) vít vách thạch cao cách nhau 24" (610 mm) oc Lớp mặt kèm theo chiều dọc và gắn chặt với 2 "(52 mm) hoặc ốc vít còn đặt 16" (406 mm) oc Khớp so le ít nhất 16 "(406 mm). | Page 88 of 103 Drawing Partition Wall W1 Single 2x4 38x89 mm wood stud wall having studs spaced 16 406 mm . with double head plate. W2 3-1 2 90 mm Unfaced Thermal Acoustic Batt Insulation filling the wall cavity. W3 Two layers of 5 8 mm SHEETROCK Brand FIRECODE C CORE gypsum panels attached directly to the studs. The panels extend through the floor cavity to the underside of the subfloor. The base layer attached vertically using 1-5 8 42 mm drywall screws spaced 24 610 mm . The face layer attached vertically and fastened with 2 52 mm or longer screws placed 16 406 mm . Joints staggered by at least 16 406 mm . W4 One layer of 5 8 mm SHEETROCK Brand FIRECODE C CORE gypsum panels attached via resilient channels. The panels attached to the channels using 1-5 8 42 mm drywall screws placed 12 305 mm . The screws placed so as not to penetrate into the studs. W5 Resilient channels spaced 24 610 mm . The resilient channels installed perpendicular to the studs using 1-5 8 42 mm drywall screws. Topping T1 3 4 19 mm OSB overlay installed perpendicular to the subfloor with staggered joints fastened with staples not less than 1 16 mm diameter and 1 2 mm crown and 1-1 2 38 mm length spaced at 6 150 mm . along edge and 8 203 mm . in the field. Floor F1 3 4 19 mm OSB floor decking fastened with 2 51 mm or longer 10 straight shank wood screws placed 6 150 mm . at edges and 12 305 mm . in the field. F2 TJI Pro 150 wood I-joists with 1-1 2 38 mm square flange and 11-7 8 300 mm depth spaced 16 406 mm . F3 6 150 mm Unfaced Thermal Acoustic Batt Insulation. F4 Resilient channels spaced 16 406 mm . The resilient channels installed perpendicular to the joists using 1-5 8 42 mm drywall screws. F5 Two layers of 5 8 mm SHEETROCK Brand FIRECODE C CORE gypsum panels. The base layer attached with the long axis perpendicular to the resilient channels using 1-5 8 42 mm or longer screws placed 12 305 mm . at the edges and 24 .

Không thể tạo bản xem trước, hãy bấm tải xuống
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.