Báo cáo y học: "Correction: Nitrogen washout/washin, helium dilution and computed tomography in the"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Critical Care giúp cho các bạn có thêm kiến thức về ngành y học đề tài: Correction: Nitrogen washout/washin, helium dilution and computed tomography in the. | Available online http content 13 2 405 Correction Correction Nitrogen washout washin helium dilution and computed tomography in the assessment of end expiratory lung volume Davide Chiumello1 Massimo Cressoni2 Monica Chierichetti2 Federica Tallarini2 Marco Botticelli2 Virna Berto2 Cristina Mietto2 and Luciano Gattinoni1 2 1 Dipartimento di Anestesia Rianimazione Intensiva e Subintensiva e Terapia del Dolore Fondazione IRCCS - Ospedale Maggiore Policlinico Mangiagalli Regina Elena via Francesco Sforza 35 20122 Milano Italy 2Istituto di Anestesiologia e Rianimazione Fondazione IRCCS - Ospedale Maggiore Policlinico Mangiagalli Regina Elena di Milano Italy Università degli Studi di Milano via Festa del Perdono 7 20122 Milano Italy Corresponding author Luciano Gattinoni gattinon@ See related research by Chiumello et al. http content 12 6 R150 Published 16 March 2009 This article is online at http content 13 2 405 2009 BioMed Central Ltd Critical Care 2009 13 405 doi cc7743 Following publication of our recent article 1 we noticed several errors relating to the figures. The complete set of correct figures follows below Figure 1 2 3 4 and 5 . The legend for Figure 5 Comparison of end expiratory lung volume EELV measured by the helium dilution technique and the nitrogen washout washin method was incorrect and should read as follows Comparison of end expiratory lung volume EELV measured by the helium dilution technique and the nitrogen washout washin method. a The EELV measured by the helium dilution as a function of the EELV measured by nitrogen washout washin method EELV helium dilution X EELV GE r2 p . b The Bland-Altman plot of the EELV measured with the nitrogen washout washin technique and the EELV measured with the helium dilution method. The x-axis shows the mean of the two measurements and the y-axis shows the difference between the EELV measured by then helium dilution method and

Bấm vào đây để xem trước nội dung
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
15    22    4    29-11-2024
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.