Biến tần fr-a700

• Features 1 • Standard High reliability is realized! (1) Equipped with small class highest level of function/performance!! (1) FR-D700 specifications 5 Safety stop function (available soon) Provided by the user (present) The FR-D700 series is compliant to the EU Machinery Directive without the addition of previously required external devices. Operation of an external Emergency Stop device results in a highly reliable immediate shutoff of the D700's output to the motor. This safety stop function conforms to the following standards. ISO13849-1 (EN954-1) Category 3 IEC60204-1 Stop Category 0 IEC61508 SIL2:Safety Integrity Level 2 150%/1Hz high starting torque by general -purpose magnetic flux vector control (2) Brake resistor can be connected • Outline dimension drawings Emergency stop Safety function is equipped •Magnetic. | Changes for the Better MITSUBISHI ELECTRIC INVERTER Model _ FR-D700 Global Standard Mitsubishi Electric Corporation Nagoya Works is a factory certified for ISO14001 standards for environmental management systems and ISO9001 standards for quality assurance managememt systems MELSOFT isoX f 14001 ị EC97J1113 051 UKAS ENVIRONMENTAL MANAGEMENT Global Standard H New standard of inverter High reliability is realized 1 Safety stop function available soon The FR-D700 series is compliant to the EU Machinery Directive without the addition of previously required external devices. Operation of an external Emergency Stop device results in a highly reliable immediate shutoff of the D700 s output to the motor. This safety stop function conforms to the following standards. IS013849-1 EN964-1 Category 3 IEC60204-1 Stop Category 0 IEC61608 SIL2 Safety Integrity Level 2 2 Provided by the user present Emergency stop For conventional model. Two MCs are necessary High cost Maintenance of two MCs is necessary Installation space is necessary Spring clamp terminal control circuit terminal Highly reliable and easy wiring is realized by the incorporation of spring clamp terminals. Main circuit terminal is screw terminal. Easy wiring Wiring is completed only by inserting wires treated with bar terminal max diameter 1 5mm Capable of wiring without a bar terminal. High reliability Spring structure in terminal contact section inside prevents contact fault by vibration. Maintenance is unnecessary Screw retightening is unnecessary. example hoist example automobile production line 3 Long-life design Most advanced life check The design life of the cooling fan has been extended to 10 years 1. The life of the fan can be further extended utilizing the it sON OEE. The longevity of the capacitors has been extended to 10 years by the adoption of a capacitor with a specification of 5000 hours and 105 C ambient temperature 1 2. 1 Ambient temperature annual average 40 C free from corrosive gas flammable gas

Không thể tạo bản xem trước, hãy bấm tải xuống
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.