CCNA 1 and 2 Companion Guide, Revised (Cisco Networking Academy Program) part 101

Cisco Networking Academy Program CCNA 1 and 2 Companion Guide, Revised part 101 is the Cisco approved textbook to use alongside version of the Cisco Networking Academy Program CCNA 1 and CCNA 2 web-based courses. The topics covered provide you with the necessary knowledge to begin your preparation for the CCNA certification exam (640-801, or 640-821 and 640-811) and to enter the field of network administration. | Page 969 Tuesday May 20 2003 4 54 PM Case Study FARB Software Development Ltd. Network Design and Implementation 969 Hints You can find the answers to these questions at the conclusion of Appendix C Check Your Understanding Answer Key. Recommendations for network equipment Look at page 1 of FloorPlan1-Desk-Assignments-building floor1 ground floor Work through the following questions What is the purpose of this floor What door will workers move freight through What doors will visitors come in Where are visitors most likely to go after they sign in Where would you consider using wireless technology Page 970 Tuesday May 20 2003 4 54 PM 970 Appendix A Structured Cabling If your department someday is tasked with wiring IP security cameras what areas would you want to keep under surveillance From where does the telephone company serve this building What kind of lock should it have Would the POP be a good place for the servers If it is determined that the server room must exist separate from the POP what considerations should guide its location Could you install the risers in the POP Page 971 Tuesday May 20 2003 4 54 PM Case Study FARB Software Development Ltd. Network Design and Implementation 971 Where might you install the risers The horizontal cabling always should go parallel to walls. Getting to Room while staying parallel to walls makes a cable run of how many meters Is this useable Floor 2 Floor 2 is dense with offices. It also contains the bottom floor of an auditorium. Not only would the auditorium be a possible candidate for wireless but it also might affect the routing of wires because it extends several floors in height. Where might you put the telecommunications room on Floor 2 You might consider using two of them. Floor 3 Floor 3 has large unplanned spaces in Rooms and . If you place the telecommunications room in Room how can you serve these spaces especially the far side of Room

Không thể tạo bản xem trước, hãy bấm tải xuống
TÀI LIỆU LIÊN QUAN
13    401    7
349    218    14
6    217    2
36    166    1
59    231    2
7    184    2
TÀI LIỆU MỚI ĐĂNG
10    71    2    29-05-2024
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.