KRONE Highband ultim8tm 8 pair disconnection modules

Tham khảo tài liệu 'krone highband ultim8tm 8 pair disconnection modules', công nghệ thông tin, phần cứng phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | KRONE HIGHBAND Ultim8 8 Pair Disconnection Modules Maximum Headroom beyond Category 6 Class E transmission performance KRONE HIGHBAND Ultim8 8 Pair Disconnection Modules Application Approvals Superior high speed data and voice cross connect modules that far exceed Category 6 component standards. HIGHBAND Ultim8 is an 8 pair disconnect module to enable high speed LAN and WAN systems maximum headroom beyond Category 6 Class E transmission performance. HIGHBAND utilises the silver plated LSA Plus contact principle. This is proven technology which has become the industry standard in over 60 countries. The gas tight contacts ensure a reliable and long lasting connection. These modules can be used in a fully patched configuration or jumpered utilising the patch by exception concept. see notes Technical Specifications ACA Compliant UL Certified Performance Ultim8 - PS NEXT - Patched Environment for use .Indoors in dry closed rooms Operating temperature range .-10 C to 60 C Maximum relative humidity 93 non-condensing Transmission performance and reliability Exceeds the ISO IEC 11801 Cat. 6 Class E standard Number of patching cycles .750 Number of wire reterminations . 200 Wire diameter range for solid and stranded copper conductors . - 26-22 AWG Wire insulation diameter range PE PVC . - Ultim8 - PS NEXT - Jumpered Patch by Exception Voltage rating .150 VAC Insulation resistance .1000 M at 500 VDC Safety .UL 1863 Flammability rating of plastic housing .UL 94 VO Notes Part Numbers HIGHBAND Ultim 8 .6468 5 060-06 Pack of 10 KRONE a When installing patch cords ensure that the latch is located at the bottom of the module and that it clips into the holes provided. b For more information on the KRONE Patch by Exception concept please contact your nearest KRONE representative A maximum of 2 equal diameter solid conductors only of up to conductor diameter can be terminated per slot. Only 1 conductor of stranded wires per slot can be terminated. If any .

Bấm vào đây để xem trước nội dung
TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
22    591    3    30-06-2024
158    383    2    30-06-2024
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.