Đang chuẩn bị liên kết để tải về tài liệu:
Supervisory Control & Data Acquisition - DAQ Networking
Không đóng trình duyệt đến khi xuất hiện nút TẢI XUỐNG
Tải xuống
Interface converter, for converting RS-232 to RS-422 and RS-485, with electrical isolation, 2 channels Bidirectional, wireless, 2400 MHz transmission system (European version), consisting of 2 transceivers (transmitter and receiver) and two antennas with connecting cable Fieldline Modular Wireless IO set, consisting of: Wireless IO base station for one Wireless IO terminal and Wireless IO device, 8 digital inputs, 8 digital outputs | Supervisory Control & Data Acquisition DAQ Networking Data Acquisition and Control Cards Master boards Remote I/O Modules Converter I/O Expansion Board Embedded Controllers Compact Embedded Controller Communication Controller Elements in DAQ Networking Feature of Remote I/O Modules Variant I/O Modules RS-485 Network 115.2K Baud Rate Maximum Self-Turner Good Expansibility Wide Voltage Source (10~30VDC) 3000 VDC Isolated Protection Variant Remote I/O Modules Analog Input V mV mA Thermocouple Analog Output V mV mA Digital Input Isolated Non-Isolated Digital Output Photo Open Collector Relay Counter Counter Frequency Noise Resistance 1.2Km (up to 4.8Km by Repeater) Noise Isolated Protection Cross Talk Signal (DT)=(D+)-(D-) D+ D- Ground Deliver Receiver Noise Signal (DT)=((D+)+Noise) - ((D-)+Noise) RS-485 type PLC Data bit: 12 bits 38400 bps Remote modules Data bit: 10 bits can be 1200, 2400 , 115200 bps Wireless modem Data bit: 10 bits 19200 bps RS-232 Device Data bit: 11 bits 9600 bps | Supervisory Control & Data Acquisition DAQ Networking Data Acquisition and Control Cards Master boards Remote I/O Modules Converter I/O Expansion Board Embedded Controllers Compact Embedded Controller Communication Controller Elements in DAQ Networking Feature of Remote I/O Modules Variant I/O Modules RS-485 Network 115.2K Baud Rate Maximum Self-Turner Good Expansibility Wide Voltage Source (10~30VDC) 3000 VDC Isolated Protection Variant Remote I/O Modules Analog Input V mV mA Thermocouple Analog Output V mV mA Digital Input Isolated Non-Isolated Digital Output Photo Open Collector Relay Counter Counter Frequency Noise Resistance 1.2Km (up to 4.8Km by Repeater) Noise Isolated Protection Cross Talk Signal (DT)=(D+)-(D-) D+ D- Ground Deliver Receiver Noise Signal (DT)=((D+)+Noise) - ((D-)+Noise) RS-485 type PLC Data bit: 12 bits 38400 bps Remote modules Data bit: 10 bits can be 1200, 2400 , 115200 bps Wireless modem Data bit: 10 bits 19200 bps RS-232 Device Data bit: 11 bits 9600 bps RS-485 type PLC Data bit: 12 bits 9600 bps Variant Baud Rate Variant Data Format Auto-Change Direction Self-Tuner Interface converter, for converting RS-232 to RS-422 and RS-485, with electrical isolation, 2 channels Bidirectional, wireless, 2400 MHz transmission system (European version), consisting of 2 transceivers (transmitter and receiver) and two antennas with connecting cable Factory Line Wireless Bluetooth Access Point Fieldline Modular Wireless IO set, consisting of: Wireless IO base station for one Wireless IO terminal and Wireless IO device, 8 digital inputs, 8 digital outputs Wireless-IO module, 16 digital inputs, 16 digital outputs, 2 analog inputs, 2 analog outputs Expansibility Converter #01 #02 #FF : : . . . . . . . RS-485 RS-232 . . . . . . . . . . . . . . RS-485 RS-485 RS-232 RS-232 COM1 COM2 COM3 Converter Converter #01 #02 #FF #01 #02 #FF Expansibility Converter : : . . . . . . . RS-485 RS-232 Comm. Controller (Address-1) . . . . . . . (Address-2) . . . . . . . .