Đang chuẩn bị liên kết để tải về tài liệu:
Analog Modules - SM 332 analog output

Không đóng trình duyệt đến khi xuất hiện nút TẢI XUỐNG

The analog output modules convert digital signals from the PLC into analog signals for the process. The modules feature the following: Resolution from 12 to 15 bit Various voltage and current ranges: The ranges are set independently for each channel using parameterization software. Interrupt capability: The module transmits diagnostic alarm messages to the controller’s CPU in the event of errors. | CA 01 Analog Modules - SM 332 analog output Analog Modules - SM 332 analog output Overview Analog outputs For the connection of analog actuators Application Analog output modules can be used to output analog signals from the PLC to the process. They are suitable for connecting analog actuators. Function The analog output modules convert digital signals from the PLC into analog signals for the process. The modules feature the following Resolution from 12 to 15 bit Various voltage and current ranges The ranges are set independently for each channel using parameterization software. Interrupt capability The module transmits diagnostic alarm messages to the controller s CPU in the event of errors. Diagnostics The module sends detailed diagnostic information to the CPU. Technical specifications 6ES7 332-5HB01-0AB0 6ES7 332-5HD01-0AB0 6ES7 332-5HF00-0AB0 6ES7 332-7ND02-0AB0 Voltages and currents Load voltage L _ Rated value DC 24 V 24 V 24 V 24 V Current consumption from load voltage L no load max. from backplane bus 5 V DC 135 mA 60 mA 240 mA 60 mA 340 mA 100 mA 290 mA 120 mA Seite 1 von 3 CA 01 Analog Modules - SM 332 analog output max. Power dissipation typical Connection system Requisite front connector Analog outputs Number of analog outputs Length of cable shielded max Voltage output short-circuit protection Voltage output short-circuit current max Current output open-circuit voltage max. Output ranges voltage _ 0 to 10 V _ 1 to 5 V _ -10 to 10 V Output ranges current _ 0 to 20 mA _ -20 to 20 mA _ 4 to 20 mA Burden resistance in the nominal output range - at voltage outputs min. - at voltage outputs capacitive load max. _ at current outputs max. _ at current outputs inductive load max. Analog value formation Integration and conversion time triggering per channel _ with over-range bits incl. sign max _ Conversion time per channel Settling time - for resistive load _ for capacitive load _ for inductive load Error accuracies Operational limit in the entire temperature

Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.