Flocculation of reactive blue 19 (RB19) using alum and the effects of catalysts addition

Không đóng trình duyệt đến khi xuất hiện nút TẢI XUỐNG

The results obtained proved that indeed after addition of catalysts, removal efficiency rates of Alum can be increased up to 25% using Calcium Hydroxide and up to 35% using Poly Aluminum Chloride compared to Alum alone. The optimum conditions for this study were at pH 5.5 ~7.5, 300 mg/L of Alum 30seconds of rapid mixing time with 300 rpm , 30rpm of mixing rate for 5 minutes and 30 minutes of settling time. | International Journal of Environment, Agriculture and Biotechnology (IJEAB) http://dx.doi.org/10.22161/ijeab/3.2.7 Vol-3, Issue-2, Mar-Apr- 2018 ISSN: 2456-1878 Flocculation of Reactive Blue 19 (RB19) using Alum and the Effects of Catalysts Addition Le Phu Tuan1, Vu Thi Kim Oanh1, Le Duy Khuong2, Nguyen Hai Hoa1, Alfienido S. Burce3 1 Vietnam National University of Forestry 2 Ha Long University 3 University of the Philippines, Diliman Abstract— There are a variety of primary coagulants which can be used in a water treatment plant. One of the earliest, and still the most extensively used, is aluminum sulfate, also known as alum. Aluminum Sulfate (Alum) is one of the most commonly used flocculent in waste water treatment processes. Effectiveness of Alum in flocculation process is determined by many factors such as the effluents pH, flocculent dose as well as the use of catalyst to improve efficiency rate of flocculation. Hence special attention to these factors especially the use of catalyst has been brought about by this study. Experiments were carried out using Reactive Blue 19 Dye as the contaminant of waste water and two catalysts namely Calcium Hydroxide (CaOH2) and Poly Aluminum Chloride (PACl) were evaluated. The results obtained proved that indeed after addition of catalysts, removal efficiency rates of Alum can be increased up to 25% using Calcium Hydroxide and up to 35% using Poly Aluminum Chloride compared to Alum alone. The optimum conditions for this study were at pH 5.5 ~7.5, 300 mg/L of Alum 30seconds of rapid mixing time with 300 rpm , 30rpm of mixing rate for 5 minutes and 30 minutes of settling time. Moreover, Alum showed the highest performance under these conditions and using 50 mg/L PACl as catalyst with 98.52% of COD reduction and 90.60% of color reduction. In conclusion, Alum with the support of PACl as catalyst is an effective coagulant, which can reduce the level of COD and Dye Color in Reactive Blue 19 contaminated wastewater. Keywords—

Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.