Đang chuẩn bị liên kết để tải về tài liệu:
A new method development and validation for identification and quantification of methoxyfenozide insecticide residues in grapes using high performance liquid chromatography

Không đóng trình duyệt đến khi xuất hiện nút TẢI XUỐNG

A simple and inexpensive method was developed using liquid - liquid extraction, together with high performance chromatographic method for determination of methoxyfenozide residues in grapes. The evaluated parameters include the extracts by distilled water and acetonitrile solvents. The method was validated using grapes samples spiked with methoxyfenozide at different fortification levels (0.05, 0.1 and 0.5 µg/g). Average recoveries (using each concentration three replicates) ranged 86-95 %, with relative standard deviations less than 5%, calibration solutions concentration in the range 0.05-5.0 µg/mL and limit of detection (LOD) and limit of quantification (LOQ) were 0.02µg/g and 0.05µg/g respectively. Finally the grapes residue samples were analyzed by HPLC. | A new method development and validation for identification and quantification of methoxyfenozide insecticide residues in grapes using high performance liquid chromatography

Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.