Đang chuẩn bị liên kết để tải về tài liệu:
báo cáo hóa học:" Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis"

Không đóng trình duyệt đến khi xuất hiện nút TẢI XUỐNG

Tuyển tập các báo cáo nghiên cứu về hóa học được đăng trên tạp chí sinh học quốc tế đề tài : Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis | Journal of Orthopaedic Surgery and Research BioMed Central Research article Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis Carlos Torrens 1 Monica Corrales1 Gemma Gonzalez1 Alberto Solano2 and Enrique Cáceres1 Address Orthopaedic Department. Hospital del Mar de Barcelona Passeig Marítim 25-29 08003 Barcelona Spain and 2Department of Radiology. Hospital del Mar de Barcelona Passeig Marítim 25-29 08003 Barcelona Spain Email Carlos Torrens - 86925@imas.imim.es Monica Corrales - MCorrales@imas.imim.es Gemma Gonzalez - GGonzalez@imas.imim.es Alberto Solano - ASolano@imas.imim.es Enrique Cáceres - ECaceres@imas.imim.es Corresponding author Open Access Published 10 October 2008 Received 26 April 2008 Journal of Orthopaedic Surgery and Research 2008 3 49 doi 10.1186 1749-799X-3-49 Accepted I0 October 2008 This article is available from http www.josr-online.com content 3 1 49 2008 Torrens et al licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License http creativecommons.org licenses by 2.0 which permits unrestricted use distribution and reproduction in any medium provided the original work is properly cited. Abstract Purpose The purpose of this study is to analyze the morphology of the scapula with reference to the glenoid component implantation in reversed shoulder prosthesis in order to improve primary fixation of the component. Methods Seventy-three 3-dimensional computed tomography of the scapula and 108 scapular dry specimens were analyzed to determine the anterior and posterior length of the glenoid neck the angle between the glenoid surface and the upper posterior column of the scapula and the angle between the major craneo-caudal glenoid axis and the base of the coracoid process and the upper posterior column. Results The anterior and posterior length of glenoid neck was classified into two groups .

TÀI LIỆU LIÊN QUAN
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.